Mic is detected and responds to voice but not generated tones

Smitty2k1

Registered
Thread Starter
Joined
Aug 28, 2024
Posts
1
More  
Preamp, Processor or Receiver
Denon x3500h
Main Amp
Hypex ncore
Front Speakers
Philharmonic
Subwoofers
SVS
Hi new REW user here. I'm using a windows 10 PC with a UMIk-1. REW/windows detects the mic and I'm able to load my cal file. I'm able to use the mic in windows and record my voice. In REW if I open the SPL meter and talk into the mic I see the SPL go up. However, when I generate a test time to set the SPL I don't see the meter respond. If I run a sweep I get no measurement.

I thought maybe it had something to do with windows built in noise suppression for mics but I've changed every setting everywhere with regards to this and can't get it working in REW!

Cheers and thanks for the software and support!
 

John Mulcahy

REW Author
Joined
Apr 3, 2017
Posts
7,996
What are you using for output? Can you hear the test tones? Please post a screenshot of your REW soundcard preferences.
 
Top Bottom